40
Model: FSH-4 Hood
Hood Cleaning & Maintenance
5.
Hood Cleaning & Maintenance
This Section describes the steps to generally maintain and clean the
FSH-4 Hood
. Attention to these procedures will
help ensure the Hood remains in satisfactory operating condition and continues to run efficiently and safely.
A
Maintenance & Service Log
is provided, see
Section 5.04
.
The Hood design incorporates various interlock switches to ensure that the unit will shutdown if certain conditions exist
that are not consistent with safe and effective operation. The interlocks should be tested
MONTHLY
as described
below. Use the
Maintenance & Service Log
to record completion of testing. If problems are detected, contact
GILES
or an authorized service provider.
NOTE: Anytime a filter access door is opened and closed, the hood must be
restarted as described in Section 4.01
.
1.
Door Interlock Test:
Start hood. With hood running, unlatch and slightly open each access doors, one at a
time. With each side confirm that hood powers
OFF
when opened and appliances under the hood cannot be
turned
ON
.
2.
Baffle Filter Test:
Remove the baffle filter from one side, then start hood. Verify that the red
[BAFFLE OR
CHARCOAL FILTER MISSING]
light turns
ON
and the
[APPLIANCE POWERED]
light turns
OFF
. Check to
ensure that appliances under Hood will not turn
ON
. Replace filter and repeat test with the other side’s
filter. See
Sections 4.02.2 & 4.02.3, Removal & Installation
.
3.
Pre-Filter/Charcoal Filter Test:
Same procedure as
#2
except perform for each pre-filter and charcoal filter,
one at a time in succession
. Reinstall the filters. See
Sections 4.02.4, 4.02.5, 4.02.8 & 4.02.9, Removal &
Installation
.
3.
E.A.C. Filter Test:
Remove one of the E.A.C. collector cells, close and latch door, then start hood. Verify that
[WASH]
light on
E.A.C. Status
comes
ON
for the side without cell and that the amber
[APPLIANCE
POWERED]
light is also
ON
. Wait approx. two (2) minutes. A beeping tone alarm should begin sounding. In
several seconds the
[APPLIANCE POWERED]
light should turn
OFF.
Check to ensure that appliances under
hood cannot be turned
ON
. Turn off hood, reinstall cell, and repeat for other side. See
Section 4.02.6. &
4.02.7, Removal & Installation
.
5.
Filter Clogged Test:
Perform this test ONLY after installing new charcoal filters
.
Start hood normally and
allow to run. Use cardboard, or other suitable material, to completely block the hood exhaust outlet,
holding it firmly in place so that no air is escaping
.
Within a few seconds, a continuous tone alarm should
begin sounding. The red
[BAFFLE OR CHARCOAL FILTER CLOGGED]
light should turn
ON
and the
[APPLIANCE
POWERED]
light should turn
OFF.
Check to ensure that appliances under hood cannot be turned
ON
.
Remove the obstruction; the alarm should silence and the
[APPLIANCE POWERED]
light should turn
ON
again.
Should any of these tests fail to yield the described results, contact a factory-authorized service company and have
the unit evaluated and repaired. A
Giles Manufacturer’s Representative
can provide information about nearby
authorized service providers, or call
GILES Services
at 800-554-4537
for assistance.
5.01
Monthly Hood Interlock Inspection (Can be Performed by User)
Содержание FSH-4 Hood
Страница 2: ......
Страница 4: ......
Страница 14: ...4 Model FSH 4 Hood Introduction ...
Страница 28: ...Model FSH 4 Overview 18 1 2 3 4 6 7 3 01 Control Panel 5 ...
Страница 30: ...20 Model FSH 4 Overview 5 2 1 3 4 6 7 8 1 5 3 4 3 02 Filter Chamber Exhaust 9 9 Not shown ...
Страница 34: ...24 Model FSH 4 Overview ...
Страница 56: ...46 Model FSH 4 Hood Troubleshooting ...
Страница 60: ...50 Model FSH 4 Hood Parts List Not shown 6 7 2 9 1 8 4 5 6 8 7 2 1 3 5 7 03 Hood Front Opened ...
Страница 62: ...52 Model FSH 4 Hood Parts List Not shown 4 5 2 1 3 1 7 04 Under Hood Filters Light ...
Страница 64: ...54 Model FSH 4 Hood Parts List Not shown 7 05 Doors Front Panel 11 8 7 9 10 1 4 2 6 3 5 12 ...
Страница 66: ...56 Model FSH 4 Hood Parts List ...
Страница 67: ......