35
Model: FSH-4 Hood
Operation & Filter Maintenance
Two L.E.D. indicator light clusters on the Control Panel show the operational status of the E.A.C. Filter system for
each side of the Hood.
4.03.3
E.A.C. Filter Status & Alarm
4.04
Filter Maintenance
[ON]
Indicates that the E.A.C. cell is installed, powered and operating. Only light
ON
when the system is
operating normally.
[WASH]
This light turns
ON
to indicate:
• Filter cell is not installed or is mis-aligned.
• Collection fins contain excessive amount of captured
grease residue.
• Poor contact with filter cell contact plate inside hood.
• Ionizer wire, or wires, completely missing.
When
[WASH]
light is
ON
, an alarm condition exists and air
cleaning is not occurring. After approximately two (2)
minutes, an intermittent (beeping) alarm tone will begin sounding and shortly thereafter, power to the
appliances under the hood is shutdown and
[APPLIANCE POWERED]
light turns
OFF
.
[WASH}
light is
NOT
intented to be a signal for routine cleaning of the cell,
DO NOT use as such
.
Typically, the collection cell must be cleaned
DAILY
to ensure optimum performance. See
Section 4.04.2,
EAC Filter Cell Cleaning
.
[CHECK]
This light turns
ON
to indicate:
• Ionizer wire broken and touching cell frame.
• Cell is damaged and has shorted out to ground.
• Collection fins are shorted out because of excessive moisture.
When
[CHECK]
light is
ON,
system is no longer operating to clean the air, even though the hood continues
to run and the appliances are powered.
DO NOT CONTINUE TO USE APPLIANCES WHEN THIS CONDITION
EXIST; DETERMINE THE CAUSE AND CORRECT!
The following actions may clear the alarm condition:
1. Turn
OFF
hood
Power Switch
.
2. Remove the E.A.C. cell and clean as described in
Section 4.04.2
.
3. Inspect the cell for broken or missing ionizer wires, bent fins, or other damage. Ionizer wires are replaceable
(when ordering replacements, note length ... available in
16” or 20”
). Bent fins may be gently straightened by
hand, such that no fins are touching adjacent fins. A cell with excessive damage (broken frame, badly bent
frame, broken insulators, etc) must be replaced.
4. Inspect the E.A.C. contact pad inside hood. Clean grease accumulation away with a mild degreasing cleaner and
dry thoroughly.
5. Replace filter cell
(
Section 4.02.7
)
and restart Hood
(Section 4.01)
. If the condition persist, contact a qualified
service technician. If none of the LED lights turn
ON
, EAC power supply may be faulty.
The following sections describe procedures necessary for cleaning and maintaining filters in the
FSH-4 Ventless
Hood
. Conscientious adherence to these procedures is essential for maintaining optimum and satisfactory hood
performance.
Содержание FSH-4 Hood
Страница 2: ......
Страница 4: ......
Страница 14: ...4 Model FSH 4 Hood Introduction ...
Страница 28: ...Model FSH 4 Overview 18 1 2 3 4 6 7 3 01 Control Panel 5 ...
Страница 30: ...20 Model FSH 4 Overview 5 2 1 3 4 6 7 8 1 5 3 4 3 02 Filter Chamber Exhaust 9 9 Not shown ...
Страница 34: ...24 Model FSH 4 Overview ...
Страница 56: ...46 Model FSH 4 Hood Troubleshooting ...
Страница 60: ...50 Model FSH 4 Hood Parts List Not shown 6 7 2 9 1 8 4 5 6 8 7 2 1 3 5 7 03 Hood Front Opened ...
Страница 62: ...52 Model FSH 4 Hood Parts List Not shown 4 5 2 1 3 1 7 04 Under Hood Filters Light ...
Страница 64: ...54 Model FSH 4 Hood Parts List Not shown 7 05 Doors Front Panel 11 8 7 9 10 1 4 2 6 3 5 12 ...
Страница 66: ...56 Model FSH 4 Hood Parts List ...
Страница 67: ......