ProfiLux 4 Resource Guide
EN
2018-13-11
96
i.
For example, if a single sensor is connected to Level 1/2, the sensor
would automatically be assigned as Level sensor #1.
2.
Connect the Leak sensor(s) to the Leak interface. (Applies ONLY to those using Leak
sensors.)
CREATING THE FUNCTION
1.
Click on the (+) icon to the left of
Probe/sensor controls
and select LEVEL.
2.
Select an unused CONTROL CIRCUIT
3.
Set the
Operation mode
to LEAKAGE DETECTION.
Maximum on-time is not involved here. No changes need to be made.
4.
If you wish to have the alarm for this function automatically reset when normal
operation is detected, check the box.
If this box is left unchecked and an alarm is triggered by this function, ProfiLux
will keep the alarm ON and keep assigned Powerbar outlet OFF. The P4 will wait
for you to manually reset the alarm.
5.
Select the sensor number that will be used for this function.
For example, if you have the Leak interface or other sensor connected to the
Level 1/2 port without a splitter, select 1.
If you are using a splitter cable on Level 1/2 and already have Level 1 assigned,
select 2.
6.
Type-in a description for this Leakage detection function and click OK.