ProfiLux 4 Resource Guide
EN
2018-13-11
81
CALIBRATION: PAB-device dosing pump
PAB-device dosing pump
1.
Click on the (+) icon to the left of
Dose
overview and select the
dosing pump to calibrate, then select the desired pump speed.
2.
Click SAVE CHANGES.
3.
Click CALIBRATE THE PUMP NOW and confirm by clicking YES. Dosing
pump will run for 1 minute and dispense fluid into collection cup.
4.
See how many ml was dispensed and enter this amount into the
Flowrate of the pump
box.
5.
Click SAVE CHANGES.
To setup dosing pump schedules, please follow the steps shown in this video:
How to create a dose schedule w/ GHL Control Center:
How to setup reminders
Want to be reminded to change light bulbs or perhaps replace your carbon/phosphate media?
Use the ProfiLux Reminders feature!
This section will show you how to create and configure reminders.
NOTE
ProfiLux 4 can support up to 16 different reminders.
To setup reminders, please follow these steps:
1.
Click on the (+) icon to the left of
Processes