ProfiLux 4 Resource Guide
EN
2018-13-11
68
OPTIONAL: Temperature Dependent Light Reduction
NOTE
ProfiLux 4 can further assist with temperature management when you use
Temperature dependent light reduction. If your tank temperature rises
higher than a maximum allowed temp, the ProfiLux can be triggered to turn
OFF specific lights for the remainder of the day.
To activate this feature, please follow these steps:
1.
Select an ILLUMINATION channel.
2.
Check the box, TEMP.-DEP. LIGHT REDUCTION.
3.
Repeat steps 1 and 2 if you want multiple Illumination channels to react to this feature.
4.
Under the Illumination drop down list, select TEMP.-DEP. LIGHTRED.
5.
Select the Temperature probe that will be responsible for controlling the assigned
Illumination channel(s).
6.
Set the SHUT OFF LIMIT.
The number you set will determine when your lights would turn off. For example,
if your Temperature probe nominal temperature is set to 77°F and shut off limit
is set to 3°F, the assigned illumination channels will turn off for the day IF
temperature reaches 80°F and above.