ProfiLux 4 Resource Guide
EN
2018-13-11
87
NOTE
This section will only show you how to get an ATO function running with a
dedicated ATO pump connected to an outlet on your powerbar.
Need a visual?
You can view our “ATO setup for ProfiLux 4“ how-to video by clicking the link
below.
1-sensor ATO setup:
2-sensor ATO setup:
https://youtu.be/1eTiG0XcBcY
TIP: GHL Doser 2.1 / Maxi as a dedicated ATO
pump
Did you know that you can use an available Doser 2.1 or Maxi dosing pump
as a dedicated ATO pump?
Click the link below to see the How-to video:
To setup ATO control, please follow these steps:
CONNECT ALL ACCESSORIES
1.
Connect a GHL Float or Optical sensor to an available Level-port on your P4.
Take note which color port on the P4 you are connecting the sensor(s) to.
i.
Purple port:
Level 1/2
ii.
Green port:
Level 3/4
If you are connecting the sensor(s) to an expansion card or Expansion Box 2, the
Level-port numbering will continue beyond Level 3/4.
i.
For example, if you have a PLM-4Level expansion card, the Level
numbering would be 5/6 for one port and 7/8 for the second port.
ii.
If you do not have any Level-port expansion cards on the P4 and instead
have an Expansion Box 2, Level 1/2 on the EXB2 would actually be Level
5/6.
If a single sensor is connected directly to a Level-port, the Level sensor will be
assigned to the first number of that Level-port.
i.
For example, if a single sensor is connected to Level 1/2, the sensor
would automatically be assigned as Level sensor #1.