ProfiLux 4 Resource Guide
EN
2018-13-11
88
CREATING THE FUNCTION
1.
Click on the (+) icon to the left of
Probe/sensor controls
and select LEVEL.
2.
Select an unused CONTROL CIRCUIT
3.
Set the
Operation mode
to AUTO TOP OFF, MIN/MAX CONTROL, OR, ATO 2 SENSORS.
The
Operation mode
you select will depend on how you wish to use the ATO
function. You can find more information on these choices in the
GCC
Walkthrough – Probe/sensor controls – Level settings
section.
4.
Set the Maximum on-time.
This is a failsafe feature that will turn OFF the assigned Powerbar outlet in case
the sensor does not respond.
5.
If you wish to have the alarm for this function automatically reset when normal
operation is detected, check the box.
If the box is left unchecked and an alarm is triggered by this function, ProfiLux
will keep the assigned Powerbar outlet OFF until you manually reset the error.
6.
Select if the ATO function should be always active. Otherwise, uncheck the box and
select which TIMER function will be responsible for activating the ATO function.
If you’d prefer to only have the ATO function run during certain times of the day,
uncheck the box. You will be required to set the TIMER function ON and OFF
times.
7.
Select the sensor number(s) that will be used for this function.
For example, if you have a single sensor connected to the Level 1/2 port and will
ONLY use 1-sensor for ATO, select 1.
If you are using a splitter cable and will use 2-sensors for ATO and have it
connected to Level 1/2, select 1 and 2.
8.
Type-in a description for this ATO function and click OK.