72
Triggered Action
•
Enable alarm output 1 / Enable alarm output 2
Select this option to enable output 1 / output 2. For details on alarm output settings, see
1.7.3 Applying Alarm I/O
and
4.2.7 Application
.
•
Record stream to SD card
Select this option to record to the local storage (SD card) for the specified period of
time for any connection failure.
In the <Pre-trigger buffer>, specify the period of time to record before the connection
failure occurs. Select <Upload for…sec> and specify the total time to record (upload) to
the SD card or select <Upload during the trigger active> to continue recording as long
as the connection failure persists. For example, if the pre-trigger buffer is 2 seconds
and <Upload for 5 sec> is selected, the recorded file will be 5 seconds in length,
including 2 seconds of recording before the connection failure occurs.
•
Send message by FTP
Select to send FTP messages when disconnection is detected.
•
Send message by E-Mail
Select to send e-mail messages when disconnection is detected.