Genie Monochrome Series-GigE Vision Camera
Network Overview & Tools
•
79
Persistent IP
•
This protocol is only suggested if the user fully controls the assignment of IP addresses on the network and a
GigE Vision camera is connected beyond routers.
•
The GigE Vision camera is forced a static IP address. The NIC IP address must use the same subnet otherwise
the camera is not accessible.
•
If the Genie camera is connected to a network with a different subnet, it cannot be accessed.
•
The DALSA network configuration tool is used to set a persistent IP address.
•
An example of a Persistent IP address assignment on a class B network:
•
Persistent IP = 192.168.1.1
•
Subnet Mask = 255.255.0.0
•
Default Gateway = 0.0.0.0
•
Warning: an incorrect IP address assignment might make it impossible to connect to the camera. In such a case
the DALSA network configuration tool includes a function to recover a Genie camera with an unknown
persistent IP and set the Genie to the factory default setting, i.e. DHCP/LLA mode. The Genie MAC address
must be known to use this function. See
"
Recovering a Camera with an Unknown Persistent IP
" on page 83 and
"
GigE Server Warning Example 2: Subnet Mask or IP error
" on page 116
.
•
For GigE Vision applications the FORCEIP command is used to force a new persistent IP or to change the IP
configuration protocol. The Genie MAC address must be known to use the FORCEIP command.
•
The following illustration shows a functional computer setup with two NIC ports, but no DHCP server. The
first uses the default LLA mode for IP addresses, while the second NIC and the Genie cameras connected to it
are configured with a persistent IP. An application on the computer can control each Genie camera, on each
subnet, without conflict.
169.254
.0.248
192.168
.0.248
Subnet
169.254
. xxx. xxx
Subnet mask
255.255 . 0 . 0
Subnet
192.168
. xxx. xxx
Subnet mask
255.255 . 0 . 0
169.254
.0.246
169.254
.0.244
192.168
.0.246
NIC
192.168.0.242
(default LLA mode)
NIC 169.254.0.242
192.168
.0.244
PCI
Persistent IP Mode:
NIC and Genie cameras are
assigned IP addresses within
the same Subnet
Содержание M1024
Страница 88: ...86 Network Overview Tools Genie Monochrome Series GigE Vision Camera...
Страница 111: ...Genie Monochrome Series GigE Vision Camera Technical Specifications 109 EC FCC Declaration of Conformity...
Страница 112: ......
Страница 126: ...124 Troubleshooting Genie Monochrome Series GigE Vision Camera...
Страница 132: ...130 Glossary of Terms Genie Monochrome Series GigE Vision Camera...