External Trigger Level-controlled Exposure
•
Also known as “Pulse Width Control” exposure. See the timing diagram below.
•
The external trigger edge initiates the exposure process. The active external trigger edge can be selected as
either the low-high or high-low transition.
•
No delay from active trigger edge to start of exposure. Note that the user must account for the input opto-
coupler electrical specifications (see "External Inputs" on page 97).
•
Exposure is stopped by the opposite edge on the trigger signal. Therefore the exposure time is defined by the
trigger pulse duration.
•
Supports
"
Reset Mode
" on page 49
trigger timing only.
External Trigger Level-controlled Exposure Timing