66
•
Operational Reference
Genie Monochrome Series-GigE Vision Camera
Acquisition Device Event Name
(case sensitive strings)
Description
Start of Trigger
Trigger is valid based on the programmed trigger parameters
Start of Exposure
Exposure has started
End of Exposure
Exposure is complete
Feature Value Changed
Parameter value is changed
Feature Info Changed
Configuration parameter is changed
Invalid Trigger
Trigger event (software or external) was invalid
Input Event 0
External Input # 1 has received a valid signal
Input Event 1
External Input # 2 has received a valid signal
Output Event 0
External Output # 1 has changed state
Output Event 1
External Output # 2 has changed state
Transfer Event Name
Description
End of frame transfer
Video frame transferred to host buffer
Event Selection via GigE Vision Compliant Applications
XML features for Events:
EventSelector
= {AcquisitionTrigger = 2, ExposureStart = 3, ExposureEnd = 4}
EventNotification
= {Off = 0, GigEVisionEvent = 1}