52
•
Operational Reference
Genie Monochrome Series-GigE Vision Camera
Input Controls via Sapera LT or GigE Vision Compliant Applications
Sapera
Genie Sapera parameters for Trigger Modes and General Inputs:
TriggerDelayToIntegration
= Delay in µs from trigger to exposure
TriggerEnable
= {FALSE, TRUE}
TriggerSource
= {Input 1 = 0, Input 2 = 1, Software = 2}
TriggerSoftware
= {FALSE, TRUE}
FramesPerTrigger
= Frame count 1 to 64k
PolarityInput_x
= {Active High = 0, Active Low = 1}
DebounceInput_x
= debouncing period in µs (from 1 to 255 µs)
See
"
Accessing Features with + LT
" on page 69
.
XML features for Trigger Modes and General Inputs:
TriggerMode
= {Off = 0, On = 1}
TriggerSelector
=
(not used)
TriggerSoftware
= Generates a software trigger to start the acquisition in software trigger mode
TriggerSource
= {Line2 = 1, Software = 2}
TriggerActivation
= {LevelLow = 0, LevelHigh = 1}
TriggerDelayAbs
= Absolute delay to apply in us after reception of the trigger signal before
starting exposure
InputLineSelector
= Index to general input {input1=0, input2=1}
InputLinePolarity
= {Active High = 0, Active Low = 1}
InputLineDebouncingPeriod
= debounce period in µs (from 1 to 255 µs)
InputLineValue
= Read input line state {low=0, high=1}
Содержание M1024
Страница 88: ...86 Network Overview Tools Genie Monochrome Series GigE Vision Camera...
Страница 111: ...Genie Monochrome Series GigE Vision Camera Technical Specifications 109 EC FCC Declaration of Conformity...
Страница 112: ......
Страница 126: ...124 Troubleshooting Genie Monochrome Series GigE Vision Camera...
Страница 132: ...130 Glossary of Terms Genie Monochrome Series GigE Vision Camera...