Advanced Operation
RS-232 / IP Commands
EDID Management
Command
Description
#edidbatolo
Read downstream EDID and stores in any Local Input
#ediddetolo
Set to default EDID on Local Input
#ediddstoba
Read downstream EDID and stores in EDID Bank
#ediddstolo
Read downstream EDID and stores into a Local EDID
#lock_edid
Locks Local EDID and disables auto-loading after
power-up
#loedidtoba
Loads Local EDID to the specified EDID bank
#ediddetolo
Loads EDID to Local EDID
#prbaedid
Read downstream EDID from bank and sends to serial
port
#prdsedid
Read downstream EDID and sends to serial port
#predidst
Spools the EDID details to the serial port
#prloedid
Read Input Local EDID and sends to serial port
#set_bank_name
Set the name of the specified EDID bank
#show_bank_name
Displays the name of the specified EDID bank
#edidbatolo
The
#edidbatolo
command
loads the EDID from the specified EDID bank and writes it to
the specified input(s). At least one input must be specified.
If
param2
= 0, then the EDID in
the specified bank is copied to all 8 inputs.
Syntax
:
#edidbatolo param1 param2 [... param9]
Parameters
:
param1
EDID bank offset
[1 ... 20]
param2 - param9
Input list
[1 ... 8]
(continued on next page)