Section 5-6 - Software Options
Section 5-6
Software Options
NOTE:
Elastography Quantification is not available in the United States of America.
NOTE:
For TUI, VOCAL II, VCI Static, STIC and OmniView, “H46352LJ - 4D Option Kit” is required.
NOTE:
Not all features or products described in this document may be available or cleared for sale in
all markets.
Table 5-5
Software Option list
Software Options
Description
Install available or not
R1
R2
R3
R4
R4.2.5x
Advanced 3D
Designed for rendering B Mode and Color Flow Mode images,
e.g., vessel trees. This is a standard feature from R2 and
onward
Yes
STD
STD
STD
STD
Auto IMT
Automatically measures the thickness of the Intima Media on
the far and near vessel walls. Near Wall IMT is the distance
between the trailing edges of the adventitia and intima; the Far
Wall IMT is the distance between the leading edges of the
adventitia and intima.
Yes
Yes
Yes
Yes
Yes
B-Flow
Intended to provide a more intuitive representation of non-
quantitative hemodynamics in vascular structures. All B-Mode
measurements are available with B-Flow active: depth, distance
along a straight line, % stenosis, volume, trace, circumference,
and enclosed area.
Yes
Yes
Yes
Yes
Yes
Coded Contrast
Provides contrast imaging capability
Yes
Yes
Yes
Yes
Yes
CW Doppler
(LS8 only)
Allows examination of blood flow data all along the Doppler
Mode cursor rather than from any specific depth. Gather
samples along the entire Doppler beam for rapid scanning of the
heart. Range gated CW allows information to be gathered at
higher velocities.
Yes
Yes
Yes
Yes
Yes
DICOM
To enable DICOM connection to network devices.
Yes
Yes
Yes
Yes
Yes
Elastography
Elastography shows the spatial distribution of tissue elasticity
properties in a region of interest by estimating the strain before
and after tissue distortion caused by external or internal forces.
The strain estimation is filtered and scaled to provide a smooth
presentation when displayed.
Yes
Yes
Yes
Yes
Yes
Elasto Quantification
Provides QAnalysis function in Elastography
Yes
Yes
Yes
Yes
Yes
Flow Quantification
Provides QAnalysis function in Flow
Yes
Yes
Yes
Yes
Yes
LOGIQView
Provides the ability to construct and view a static B-Mode image
which is wider than the field of view of a given transducer. This
feature allows viewing and measurements of anatomy that is
larger than what would fit in a single image. Examples include
scanning of vascular structures and connective tissues in the
arms and legs.
Yes
Yes
Yes
Yes
Yes
Report Writer
Provides output to external printers
Yes
Yes
Yes
Yes
Yes
Содержание LOGIQ S8
Страница 11: ...GE HEALTHCARE DIRECTION 5394227 12 LOGIQ S8 LOGIQ E8 SERVICE MANUAL ix ZH CN KO...
Страница 12: ...GE HEALTHCARE DIRECTION 5394227 12 LOGIQ S8 LOGIQ E8 SERVICE MANUAL x...
Страница 16: ...GE HEALTHCARE DIRECTION 5394227 12 LOGIQ S8 LOGIQ E8 SERVICE MANUAL xiv This page was intentionally left blank...
Страница 32: ...GE HEALTHCARE DIRECTION 5394227 12 LOGIQ S8 LOGIQ E8 SERVICE MANUAL 16...
Страница 176: ...GE HEALTHCARE PROPRIETARY TO GE DIRECTION 5394227 12 LOGIQ S8 LOGIQ E8 SERVICE MANUAL 3 98 Section 3 16 Paperwork...
Страница 416: ...GE HEALTHCARE DIRECTION 5394227 REVISION 12 LOGIQ S8 LOGIQ E8 SERVICE MANUAL Index 4...
Страница 417: ......