Housing Installation
CyberDome Series Installation Manual
14
A06-8SG0/B/April2006/1033921C
Step 13)
Push the CyberDome upper housing through the hole and position the housing’s
three mounting holes to match those in the ceiling. Use the remaining three
screws to secure the housing to the ring.
CAUTION!
DO NOT connect the 24VAC power cable to the video or RS422 connection in step 11 (below), or the
CyberDome will be damaged.
Step 11)
Connect the prepared cables to the interface module. See
Figure 15
.
There are two versions of the CyberDome interface module depending on whether
video is being sent via coaxial cable (CyberDome Coaxial Interface Module) or
unshielded twisted-pair wire (CyberDome UTP Interface Module).
NOTE: When using the CyberDome UTP Interface Module, the unshielded twisted-
pair video and RS422 control wires can share the same wire jacket, but must remain
as separate twisted pairs.
Step 12)
Insert the interconnect cable from the CyberDome into the RJ45 jack in the inter-
face module. See
Figure 15
.
Figure 16: Securing the Upper Housing
Figure 15: Connecting the Cables to Either CyberDome Interface Module
Step 14)
Proceed to
RS422 Termination
on page 31.