GE Multilin
C60 Breaker Protection System
2-13
2 PRODUCT DESCRIPTION
2.2 ORDER CODES
2
The order codes for the reduced size vertical mount units with the process bus module are shown below.
|
81
|
|
|
|
Eight-port digital process bus module
DIGITAL INPUTS/OUTPUTS
XX
XX
XX
None
4A
4A
|
4 Solid-State (no monitoring) MOSFET outputs
4B
4B
|
4 Solid-State (voltage with optional current) MOSFET outputs
4C
4C
|
4 Solid-State (current with optional voltage) MOSFET outputs
4D
4D
|
16 digital inputs with Auto-Burnishing (maximum of three modules within a case)
4L
4L
|
14 Form-A (no monitoring) Latching outputs
67
67
|
8 Form-A (no monitoring) outputs
6A
6A
|
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 digital inputs
6B
6B
|
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 digital inputs
6C
6C
|
8 Form-C outputs
6D
6D
|
16 digital inputs
6E
6E
|
4 Form-C outputs, 8 digital inputs
6F
6F
|
8 Fast Form-C outputs
6G
6G
|
4 Form-A (voltage with optional current) outputs, 8 digital inputs
6H
6H
|
6 Form-A (voltage with optional current) outputs, 4 digital inputs
6K
6K
|
4 Form-C and 4 Fast Form-C outputs
6L
6L
|
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 digital inputs
6M
6M
|
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 digital inputs
6N
6N
|
4 Form-A (current with optional voltage) outputs, 8 digital inputs
6P
6P
|
6 Form-A (current with optional voltage) outputs, 4 digital inputs
6R
6R
|
2 Form-A (no monitoring) and 2 Form-C outputs, 8 digital inputs
6S
6S
|
2 Form-A (no monitoring) and 4 Form-C outputs, 4 digital inputs
6T
6T
|
4 Form-A (no monitoring) outputs, 8 digital inputs
6U
6U
|
6 Form-A (no monitoring) outputs, 4 digital inputs
6V
6V
|
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 digital inputs
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
2A
C37.94SM, 1300 nm single-mode, ELED, 1 channel single-mode
2B
C37.94SM, 1300 nm single-mode, ELED, 2 channel single-mode
2G
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
2I
Channel 1 - IEEE C37.94, multimode, 64/128 kbps; Channel 2 - 1300 nm, single-mode, Laser
2J
Channel 1 - IEEE C37.94, multimode, 64/128 kbps; Channel 2 - 1300 nm, single-mode, Laser
72
1550 nm, single-mode, Laser 1 Channel
73
1550 nm, single-mode, Laser, 2 Channel
74
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, Laser
75
Channel 1 - G.703; Channel 2 - 1550 nm, single-mode Laser
76
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A
820 nm, multimode, LED, 1 Channel
7B
1300 nm, multimode, LED, 1 Channel
7C
1300 nm, single-mode, ELED, 1 Channel
7D
1300 nm, single-mode, Laser, 1 Channel
7E
Channel 1 - G.703; Channel 2 - 820 nm, multimode
7F
Channel 1 - G.703; Channel 2 - 1300 nm, multimode
7G
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H
820 nm, multimode, LED, 2 Channels
7I
1300 nm, multimode, LED, 2 Channels
7J
1300 nm, single-mode, ELED, 2 Channels
7K
1300 nm, single-mode, LASER, 2 Channels
7L
Channel 1 - RS422; Channel 2 - 820 nm, multimode, LED
7M
Channel 1 - RS422; Channel 2 - 1300 nm, multimode, LED
7N
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
7P
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, LASER
7Q
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode LASER
7R
G.703, 1 Channel
7S
G.703, 2 Channels
7T
RS422, 1 Channel
7W
RS422, 2 Channels
Table 2–7: C60 ORDER CODES (REDUCED SIZE VERTICAL UNITS WITH PROCESS BUS MODULE)
C60
-
*
**
- *
*
* - F
**
- H
**
- M
**
-
P/R
**
Reduced Size Vertical Mount (see note regarding P/R slot below)
BASE UNIT
C60
|
|
|
|
|
|
|
|
|
Base Unit
CPU
T
|
|
|
|
|
|
|
|
RS485 with 3 100Base-FX Ethernet, multimode, SFP with LC
U
|
|
|
|
|
|
|
|
RS485 with 1 100Base-T Ethernet, SFP RJ-45 + 2 100Base-FX Ethernet, multimode, SFP with LC
V
|
|
|
|
|
|
|
|
RS485 with 3 100Base-T Ethernet, SFP with RJ-45
SOFTWARE
00
|
|
|
|
|
|
|
No Software Options
01
|
|
|
|
|
|
|
Ethernet Global Data (EGD)
03
|
|
|
|
|
|
|
IEC 61850
04
|
|
|
|
|
|
|
Ethernet Global Data (EGD) and IEC 61850
14
|
|
|
|
|
|
|
Two Phasor Measurement Units (PMUs)
15
|
|
|
|
|
|
|
IEC 61850 and two PMUs
A0
|
|
|
|
|
|
|
CyberSentry Lvl 1
A1
|
|
|
|
|
|
|
CyberSentry Lvl 1 and Ethernet Global Data
A3
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850
A4
|
|
|
|
|
|
|
CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
AE
|
|
|
|
|
|
|
CyberSentry Lvl 1 and two PMUs
AF
|
|
|
|
|
|
|
CyberSentry Lvl 1, IEC 61850, and two PMUs
B0
|
|
|
|
|
|
|
IEEE 1588
B1
|
|
|
|
|
|
|
IEEE 1588 and Ethernet Global Data
B3
|
|
|
|
|
|
|
IEEE 1588 and IEC 61850
B4
|
|
|
|
|
|
|
IEEE 1588, Ethernet Global Data, and IEC 61850
BE
|
|
|
|
|
|
|
IEEE 1588 and two PMUs
BF
|
|
|
|
|
|
|
IEEE 1588, IEC 61850, and two PMUs
C0
|
|
|
|
|
|
|
Parallel Redundancy Protocol (PRP)
C1
|
|
|
|
|
|
|
PRP and Ethernet Global Data
C3
|
|
|
|
|
|
|
PRP and IEC 61850
C4
|
|
|
|
|
|
|
PRP, Ethernet Global Data, and IEC 61850
CE
|
|
|
|
|
|
|
PRP and two PMUs
CF
|
|
|
|
|
|
|
PRP, IEC 61850, and two PMUs
D0
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1
D1
|
|
|
|
|
|
|
IEEE 1588, CyberSentry Lvl 1, and Ethernet Global Data
D3
|
|
|
|
|
|
|
IEEE 1588, CyberSentry Lvl 1, and IEC 61850
D4
|
|
|
|
|
|
|
IEEE 1588, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
DE
|
|
|
|
|
|
|
IEEE 1588, CyberSentry Lvl 1, and two PMUs
DF
|
|
|
|
|
|
|
IEEE 1588, CyberSentry Lvl 1, IEC 61850, and two PMUs
E0
|
|
|
|
|
|
|
IEEE 1588 and PRP
E1
|
|
|
|
|
|
|
IEEE 1588, PRP, and Ethernet Global Dada
E3
|
|
|
|
|
|
|
IEEE 1588, PRP, and IEC 61850
E4
|
|
|
|
|
|
|
IEEE 1588, PRP, Ethernet Global Data, and IEC 61850
EE
|
|
|
|
|
|
|
IEEE 1588, PRP, and two PMUs
EF
|
|
|
|
|
|
|
IEEE 1588, PRP, IEC 61850, and two PMUs
F0
|
|
|
|
|
|
|
PRP and CyberSentry Lvl1
F1
|
|
|
|
|
|
|
PRP, CyberSentry Lvl1, and Ethernet Global Data
F3
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, and IEC 61850
F4
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
FE
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, and two PMUs
FF
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, IEC 61850, and two PMUs
G0
|
|
|
|
|
|
|
IEEE 1588, PRP, and CyberSentry Lvl 1
G1
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, Ethernet Global Data
G3
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850
G4
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
GE
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, and two PMUs
GF
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and two PMUs
J0
|
|
|
|
|
|
|
IEC 60870-5-103
J1
|
|
|
|
|
|
|
IEC 60870-5-103 and EGD
J3
|
|
|
|
|
|
|
IEC 60870-5-103 and IEC 61850
J4
|
|
|
|
|
|
|
IEC 60870-5-103, EGD, and IEC 61850
JE
|
|
|
|
|
|
|
IEC 60870-5-103 and two PMUs
JF
|
|
|
|
|
|
|
IEC 60870-5-103, IEC 61850, and two PMUs
K0
|
|
|
|
|
|
|
IEEE 1588, PRP, and IEC 60870-5-103
K1
|
|
|
|
|
|
|
IEEE 1588, PRP, IEC 60870-5-103, and EGD
Table 2–6: C60 ORDER CODES (HORIZONTAL UNITS WITH PROCESS BUS MODULE)
C60
-
*
**
- *
*
* - F
**
- H
**
- M
**
- P
**
- U
**
- W/X
**
Full Size Horizontal Mount
Содержание C60
Страница 10: ...x C60 Breaker Protection System GE Multilin TABLE OF CONTENTS ...
Страница 30: ...1 20 C60 Breaker Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 420: ...5 284 C60 Breaker Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 423: ...GE Multilin C60 Breaker Protection System 6 3 6 ACTUAL VALUES 6 1 OVERVIEW 6 FIRMWARE REVISIONS See page 6 28 ...
Страница 466: ...8 4 C60 Breaker Protection System GE Multilin 8 1 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Страница 478: ...9 12 C60 Breaker Protection System GE Multilin 9 6 DISPOSAL 9 MAINTENANCE 9 ...
Страница 492: ...A 14 C60 Breaker Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 648: ...E 10 C60 Breaker Protection System GE Multilin E 1 OVERVIEW APPENDIX E E ...
Страница 660: ...F 12 C60 Breaker Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 670: ...H 8 C60 Breaker Protection System GE Multilin H 2 ABBREVIATIONS APPENDIX H H Z Impedance Zone ...
Страница 672: ...H 10 C60 Breaker Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Страница 682: ...x C60 Breaker Protection System GE Multilin INDEX ...