GREER COMPANY
Crane Systems
GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 TEL: (714) 259-9702 FAX: (714) 259-7626
MicroGuard® RCI 510/400 CALIBRATION MANUAL PN W450189A 09/09/02
48 of 65
COMMAND 12 WINCHES
Command 12 permits "
hiding
" a winch that is not in use or "
activating
" a winch that is
hidden. Winches are classified as “active” or “hidden.” Watch the display screen showing the
two winches. After completing the routine below, a green light will flash above the active winch.
TO HIDE OR ACTIVATE A WINCH:
1)
PRESS
A
TO
12
WINCHES
.
2)
PRESS
C
TO START THE COMMAND.
3)
PRESS
B
TO TOGGLE BETWEEN THE TWO WINCHES.
4)
PRESS
C
TO CHANGE FROM ‘SELECTABLE’ TO ‘HIDDEN’ (OR VICE VERSA).
5)
PRESS
C
TO CALIBRATE OR
PRESS D
TO ABORT THE CALIBRATION.
6)
PRESS
D
TO EXIT THE ROUTINE.
COMMAND 13 ATTACHMENTS
Command 13
permits ”
hiding
” an
attachment
not in use or returning a hidden
attachment to a ”
selectable
” (active) status.
1)
PRESS
A
TO COMMAND
13 ATTACHMENTS
.
2)
PRESS
C
TO START THE COMMAND.
3)
PRESS
B
TO THE ATTACHMENT TO BE CHANGED.
4)
PRESS
C
TO CHANGE FROM ‘SELECTABLE’ TO ‘HIDDEN’ OR VICE VERSA.
5)
PRESS
C
TO CALIBRATE OR
PRESS D
TO ABORT CALIBRATION.
6)
PRESS D