GREER COMPANY
Crane Systems
GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 TEL: (714) 259-9702 FAX: (714) 259-7626
MicroGuard® RCI 510/400 CALIBRATION MANUAL PN W450189A 09/09/02
30 of 65
ORs Full
9.7Klb Ctwt
ERECTED 60' TELEJIB 17 AUXHD ON
PICK FROM MAIN BOOM FRONT WINCH
TEST
MAX
SET
360
o
6
23,500
i2,300
44.8
62.7
26.4
o
CONFIGURATION SELECTION
continued
PARTS-OF-LINE
Press and hold 2
↓
or 2
↑
to view the available
parts-of-line
. The latest value (2x) appears when
the button is released. This number applies only to the winch currently selected. A value,
however, must be entered for
both
winches.
WINCH
Refer to the illustration above.
After the initial setup, the system records the parts-of-line (2x), lifting point (14), and permits
calculation of deducts (6) for each winch.
Press
19 to switch back and forth between the first
and second winch. The red led’s on the
winch
(19) indicate the current winch selected (if using
two winches) and are lifting from two separate picking points.
RIGGING TRAVEL MODE
The Rigging/Travel Mode (21) may be selected as part of the carrier options. When selected,
this mode controls the rigging and travel of the crane by inhibiting crane motion and silencing
the audible alarm. The display readout is restricted to radius, length, angle, height, and
precautionary messages.
See the notes on page 29.
B
2
↑
19
21
2
↓
2X
14
Parts-of-Line
D
C
A
6