GREER COMPANY
Crane Systems
GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 TEL: (714) 259-9702 FAX: (714) 259-7626
MicroGuard® RCI 510/400 CALIBRATION MANUAL PN W450189A 09/09/02
6 of 65
ENTERING THE CALIBRATION MODE
To perform any calibration routine, the System must operate in the “Calibration Mode.” To
access the Calibration Mode,
press
the
Test
and
Set keys
simultaneously for approximately
two seconds
.
ENTERING THE CALIBRATION SECURITY CODE
Entry of the
Calibration Security Code
will be required often throughout these procedures
.
Press keys 1 2 3 4
below
in
this
sequence to enter the Calibration Security
Code.
If the wrong sequence is used or if the entry is not completed within 5 seconds, the entry
will be aborted and must be entered again. This code will be used often throughout these
routines. It is helpful to memorize these key positions.
ORs Full
9.7Klb Ctwt
ERECTED 60' TELEJIB 17 AUXHD ON
PICK FROM MAIN BOOM FRONT WINCH
TEST
MAX
SET
360
o
6
23,500
i2,300
44.8
62.7
26.4
o
3
2
4
1
THE RCI 510/400 DISPLAY