MicroGuard® RCI 510/400 CALIBRATION MANUAL PN W450189A 09/09/02
20 of 65
COMMAND 03 ZERO - BOOM ANGLE SENSOR
Use great care when calibrating the boom angle sensor.
All subsequent calculations are
dependent on the accuracy of this calibration.
Use an inclinometer or measuring device with an accuracy of +/- 0.25 when calibrating the
boom angle sensor. Use of a less accurate device may result in calibration errors.
IMPORTANT:
Ensure that the boom is in a horizontal position
when performing this routine
.
♦
Using an inclinometer, set the boom in a horizontal position.
♦
The boom angle sensor is mounted inside the d3l0022 housing.
Mount the extension sensor perpendicular to the boom.
♦
Calibrate the zero of the boom angle sensor (page 21).