GREER COMPANY
Crane Systems
GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 TEL: (714) 259-9702 FAX: (714) 259-7626
MicroGuard® RCI 510/400 CALIBRATION MANUAL PN W450189A 09/09/02
19 of 65
COMMAND 03 ZERO - EXTENSION SENSOR
CONTINUED
COMMAND 03 ZERO ROUTINE – EXTENSION SENSOR
IMPORTANT:
Ensure that the boom is in a horizontal position when performing this routine.
1)
PRESS
A
TO
03 ZERO SENSOR.
2)
PRESS
C
TO START THE COMMAND.
3)
PRESS
A
TO ZERO NO. 2 XXXX
(ACTUAL INPUT)
.
4)
PRESS
C
TO START CALIBRATION OF THE 03 ZERO SENSOR.
5)
PRESS
C
TO CALIBRATE OR
PRESS D
TO ABORT THE CALIBRATION OF ZERO NO. 2.
AFTER THE MESSAGE,
“CALIBRATING”
ENDS
,
THE DISPLAY SHOULD READ:
ZERO NO. 2 XXXX
(ZEROED INPUT).
6)
PRESS
D
TO EXIT THE ROUTINE OR
PRESS
A
TO CHANGE THE SENSOR.
ORs Full
9.7Klb Ctwt
ERECTED 60' TELEJIB 17 AUXHD ON
PICK FROM MAIN BOOM FRONT WINCH
TEST
MAX
SET
360
o
6
23,500
i2,300
44.8
62.7
26.4
o
C
D
B
A
03 Zero Sensor