MicroGuard® RCI 510/400 CALIBRATION MANUAL PN W450189A 09/09/02
41 of 65
COMMAND 07 RADIUS/MOMENT MAIN BOOM
continued
THIRD LENGTH
MAINTAIN THE SAME LOW ANGLE AND FULLY EXTEND THE MAIN BOOM.
MEASURE THE NEW RADIUS.
25)
THE
DISPLAY SHOULD STILL READ:
Bas2
( )
.
26)
PRESS
C
TO STORE THE LOW ANGLE DATA. THE HOOK(S)
MUST BE ABOVE THE GROUND AND SUPPORTED BY THE BOOM ONLY.
27)
USE THE NUMBER ENTRY ROUTINE (PAGE 14) TO ENTER THE
NEW
RADIUS.
28)
THE DISPLAY SHOULD READ:
Bas2 (D )
(LOW ANGLE DATA ACQUIRED).
29)
PRESS
C
TO START THE CALIBRATION AT THE CURRENT LENGTH.
30)
PRESS
C
TO CALIBRATE OR
PRESS D
TO ABORT THE CALIBRATION.
THIRD LENGTH
CONTINUED
RAISE THE FULLY EXTENDED BOOM TO AN ANGLE BETWEEN 60
°
AND 65
°
.
MEASURE THE NEW RADIUS.
31)
THE DISPLAY SHOULD STILL READ:
Bas2
(D ).
32)
PRESS
C
TO STORE THE HIGH ANGLE DATA.
THE HOOK(S) MUST BE ABOVE THE GROUND AND SUPPORTED BY THE
BOOM ONLY.
33)
USE THE NUMBER ENTRY ROUTINE (PAGE 14), TO ENTER THE
NEW
RADIUS.
34)
THE DISPLAY SHOULD READ
:
Bas2 (DU)
(LOW/HIGH ANGLE DATA
ACQUIRED).
35)
PRESS
C
TO START THE MOMENT CALIBRATION AT THE CURRENT LENGTH.
36)
PRESS
C
TO CALIBRATE OR
PRESS
D
TO ABORT THE CALIBRATION.
37)
PRESS
D
TO EXIT THE ROUTINE.
CARRY OUT COMMAND 08 BDC PRIOR TO DOING THE MAIN BOOM + MANUAL RADIUS AND
MOMENT CALIBRATION.
IF THERE IS A MANUAL SECTION OR MODE B EQUIPPED ON THE CRANE, RETURN TO
COMMAND 07 AFTER COMPLETING THE BDC FOR THE MAIN BOOM.