COMMAND 04 SPAN
continued
EXTENSION SENSOR
The fully extended boom with no load (3 section or 4 section) will not cause a tipping condition.
Carry out the calibration procedure below with the main boom sections fully extended.
The
“extension value” is the fully extended boom length minus the fully retracted
boom length.
COMMAND 04 SPAN – EXTENSION SENSOR ROUTINE
If continuing from span 3 on page 23, go directly to step 4 below:
1)
PRESS
A
TO
04 SPAN SENSOR.
2)
PRESS
C
TO START THE COMMAND.
3)
PRESS
B
TO SPAN NO. 2.
4)
FULLY EXTEND THE BOOM.
5)
PRESS
C
TO CONFIRM SELECTION OF THE SENSOR.
6)
PRESS
C
TO START THE CALIBRATION OF SPAN NO. 2.
7) USE THE FORMULA ABOVE TO DETERMINE THE EXTENSION VALUE.
8)
USE THE NUMBER ENTRY PROCEDURE (PAGE 14). TO ENTER THE
EXTENSION VALUE.
9)
AFTER THE MESSAGE,
“CALIBRATING”
ENDS
,
THE DISPLAY SHOULD READ: Span NO. 2 XXXX (EXTENSION VALUE).
10)
PRESS
D
TO
EXIT THE ROUTINE.
The above procedure will show the boom extension as the EXTENSION VALUE (xx FT.). After completion of
COMMAND 07 (Main Boom radius/moment), the display will exhibit THE ACTUAL BOOM LENGTH.
ORs Full
9.7Klb Ctwt
ERECTED 60' TELEJIB 17 AUXHD ON
PICK FROM MAIN BOOM FRONT WINCH
TEST
MAX
SET
360
o
6
23,500
i2,300
44.8
62.7
26.4
o
04 Span Sensor
B
D
C