MicroGuard® RCI 510/400 CALIBRATION MANUAL PN W450189A 09/09/02
17 of 65
COMMAND 03 ZERO - PRESSURE TRANSDUCERS
continued
COMMAND 03 ZERO ROUTINE - PRESSURE TRANSDUCERS
IMPORTANT:
ENSURE THAT THE BOOM IS IN A HORIZONTAL POSITION WHEN PERFORMING THIS
ROUTINE.
1)
PRESS A
TO
03 ZERO SENSOR
.
2)
PRESS C
TO
START THE COMMAND.
THE DISPLAY SHOULD READ:
ZERO TX. 0 XXXX (ACTUAL input).
3)
PRESS C
TO START CALIBRATION OF TX. 0. SENSOR.
4)
PRESS C
TO
CALIBRATE OR
PRESS D
TO ABORT THE CALIBRATION OF TX. 0.
AFTER THE MESSAGE,
“CALIBRATING”
ENDS
,
THE DISPLAY SHOULD READ:
ZERO TX. 0 XXXX (ZEROED input).
5)
PRESS A
TO ZERO TX. 1. 0.
6)
PRESS C
TO START CALIBRATION OF TX.1 SENSOR.
7)
PRESS C
TO CALIBRATE OR
PRESS D
TO ABORT THE CALIBRATION OF TX. 1.
AFTER THE MESSAGE,
“CALIBRATING”
ENDS
,
THE DISPLAY SHOULD READ:
ZERO TX.1 XXXX
(ZEROED input).
8)
PRESS D
TO EXIT ROUTINE.
Reconnect all hydraulic lines and reinstall the tank pressure relief valve before resuming crane
operation.