GREER COMPANY
Crane Systems
GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 TEL: (714) 259-9702 FAX: (714) 259-7626
MicroGuard® RCI 510/400 CALIBRATION MANUAL PN W450189A 09/09/02
44 of 65
COMMAND 07 MAIN BOOM - RADIUS/MOMENT
MAIN BOOM + MANUAL
continued
FIRST LENGTH
continued
Raise the retracted boom to an angle between 60
°
and 65
°
. Measure the new
radius.
7)
THE DISPLAY SHOULD STILL READ:
Bas0(D )
.
8)
PRESS C
TO STORE THE HIGH ANGLE DATA. THE HOOK(S) MUST BE ABOVE THE
GROUND AND SUPPORTED BY THE BOOM ONLY.
9)
USE THE NUMBER ENTRY ROUTINE (PAGE 14) TO ENTER THE
NEW
RADIUS.
THE DISPLAY SHOULD READ
:
Bas0 (DU)
(LOW/HIGH ANGLE DATA
ACQUIRED).
10)
PRESS C
TO START THE MOMENT CALIBRATION AT THE CURRENT LENGTH.
11)
PRESS C
TO CALIBRATE
OR
PRESS D
TO ABORT THE CALIBRATION.
12) THE DISPLAY SHOULD READ:
Bas1 ( ).
.
SECOND LENGTH
Maintain the same high angle and extend the boom to 50% of boom extension. Measure
the new radius.
13)
THE DISPLAY SHOULD STILL READ:
Bas1 ( )
.
14)
RAISE THE HOOKS CLOSE TO THE BOOM TIP (THIS REMOVES EXCESS
ROPE WEIGHT FROM THE BOOM).
15)
PRESS C
TO STORE THE HIGH ANGLE DATA
16) USE THE NUMBER ENTRY ROUTINE (PAGE 14) TO ENTER THE
NEW
RADIUS.
!7)
THE DISPLAY SHOULD READ:
Bas1( U) (HIGH ANGLE DATA
ACQUIRED).
SECOND LENGTH
continued
Maintain the same length and lower the boom to 5 °. Measure the new radius.
18)
THE DISPLAY SHOULD STILL READ:
Bas1 ( U).
19)
PRESS
C
TO STORE THE LOW ANGLE DATA. THE HOOK(S) MUST BE ABOVE THE
GROUND AND SUPPORTED BY THE BOOM ONLY.
20)
USE THE NUMBER ENTRY ROUTINE TO ENTER THE
NEW
RADIUS.
21)
THE DISPLAY SHOULD READ:
Bas1
(DU). (LOW/HIGH ANGLE DATA
ACQUIRED).