GREER COMPANY
Crane Systems
GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 TEL: (714) 259-9702 FAX: (714) 259-7626
MicroGuard® RCI 510/400 CALIBRATION MANUAL PN W450189A 09/09/02
28 of 65
COMMAND 05/2 SWING - DIRECTION
Swing direction is similar to a compass. Swinging to the right will increase and swinging to the
left will decrease the readings. If the swing potentiometer is mounted so that output is in the
wrong direction, use the direction command to change the displayed direction.
COMMAND 05 SWING ROUTINE - DIRECTION
If continuing from Command 05/1, page 27, skip to No. 4 below.
1)
PRESS
A
TO
05 SWING POTENTIOMETER.
2)
PRESS
C
TO CONFIRM THE SELECTION.
3)
PRESS
A
TO 2 SET SWING DIRECTION - (can be plus + or minus -)
4)
PRESS
C
TO START CALIBRATION OF 2 DIRECTION.
5)
PRESS
C
TO CALIBRATE OR
PRESS D
TO ABORT THE CALIBRATION.
IN THIS CASE FOLLOWING CALIBRATION, THE DISPLAY SHOULD READ:
2 SET SWING
DIR THUS REVERSING THE PREVIOUS DIRECTION (-
).
6)
PRESS
B
TO VIEW ACTUAL ANGLE OF SWING POT ZERO.
7)
ROTATE
THE UPPER APPROXIMATELY 10
°
TO THE RIGHT.THE NUMBERS
SHOULD
INCREASE
.
8)
ROTATE
THE UPPER APPROXIMATELY 10
°
TO THE LEFT. THE NUMBERS
SHOULD
DECREASE
.
9)
IF NUMBERS DO NOT CHANGE IN STEPS 7 AND 8, AS INDICATED, RETURN TO
STEP 4 AND REPEAT THE ENTIRE ROUTINE.
10)
PRESS
D
TO EXIT THE ROUTINE.
ORs Full
9.7Klb Ctwt
ERECTED 60' TELEJIB 17 AUXHD ON
PICK FROM MAIN BOOM FRONT WINCH
TEST
MAX
SET
360
o
6
23,500
i2,300
44.8
62.7
26.4
o
05 Swing Potentiometer
B
D
C
A