GREER COMPANY
Crane Systems
GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 TEL: (714) 259-9702 FAX: (714) 259-7626
MicroGuard® RCI 510/400 CALIBRATION MANUAL PN W450189A 09/09/02
43 of 65
COMMAND 07 MAIN BOOM + MANUAL - RADIUS/MOMENT
(
D
) = LOW ANGLE DATA ACQUIRED. (
U
) = HIGH ANGLE DATA ACQUIRED.
(
DU
) = HIGH AND LOW ANGLE DATA ACQUIRED.
COMMAND 07 RADIUS/MOMENT ROUTINE - MAIN BOOM + MANUAL
Before starting this routine, carefully review the material on page 42.
FIRST LENGTH
Exit the calibration Mode. From the normal working screen, select Main
Boom + Manual. Extend the Manual section and fully retract the boom to an
angle of 5
°
or less.
Determine the weight of the hook-block in use. If an auxillary hook is fitted, its weight must also
be added to the main hook weight.
Example: if hook block(s) = 1200 lbs., the number
for entry would be 1.2.
Return to the calibration Mode.
1)
PRESS
A
TO
07 RADIUS/ MOMENT.
2)
PRESS
C
TO START THE COMMAND.
3)
USE THE NUMBER ENTRY ROUTINE (PAGE 14) TO ENTER THE WEIGHT
OF THE HOOK-BLOCK(S). THE DISPLAY SHOULD READ:
Bas0
( ).
4)
PRESS
C
TO STORE THE LOW ANGLE DATA. (THE HOOK(S) MUST BE ABOVE THE
GROUND AND SUPPORTED BY THE BOOM ONLY.)
5) USE NUMBER ENTRY ROUTINE ( PAGE 14) TO ENTER
CURRENT
RADIUS.
6)
THE DISPLAY SHOULD READ:
Bas0 (D )
(LOW ANGLE DATA ACQUIRED).
ORs Full
9.7Klb Ctwt
ERECTED 60' TELEJIB 17 AUXHD ON
PICK FROM MAIN BOOM FRONT WINCH
TEST
MAX
SET
360
o
6
23,500
i2,300
44.8
62.7
26.4
o
07 Radius/Moment
B
D
C
A