GREER COMPANY
Crane Systems
GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 TEL: (714) 259-9702 FAX: (714) 259-7626
MicroGuard® RCI 510/400 CALIBRATION MANUAL PN W450189A 09/09/02
55 of 65
COMMAND 16 ROPE DATA
continued
1)
PRESS
A
TO
16 ROPE DATA
.
2)
PRESS
C
TO START THE COMMAND.
THE DISPLAY SHOULD READ:
CURRENT VALUE (EXAMPLE: 12.000).
3)
PRESS
C
TO START THE CALIBRATION OF
ROPE LIMIT #0.
4)
PRESS
C
TO CALIBRATE OR
PRESS D
TO ABORT THE CALIBRATION.
5)
USE THE NUMBER ENTRY PROCEDURE TO ENTER THE
NEW LIMIT.
AFTER THE MESSAGE, “CALIBRATING,” THE DISPLAY SHOULD READ:
CURRENT VALUE XX.XXX.
6)
PRESS
A
TO
ROPE LIMIT #1.
THE DISPLAY SHOULD READ:
CURRENT VALUE (EXAMPLE: 9.080
).
7)
PRESS
C
TO START THE CALIBRATION OF
ROPE LIMIT #1.
8)
PRESS
C
TO CALIBRATE OR
PRESS D
TO ABORT THE CALIBRATION.
9)
USE
THE
NUMBER
ENTRY
PROCEDURE (PAGE 14) TO ENTER THE
NEW
LIMIT
.
AFTER THE MESSAGE,"
CALIBRATING
," THE DISPLAY SHOULD READ:
CURRENT VALUE (XX.XXX)
.
10)
PRESS
D
TO EXIT THE ROUTINE.
ORs Full
9.7Klb Ctwt
ERECTED 60' TELEJIB 17 AUXHD ON
PICK FROM MAIN BOOM FRONT WINCH
TEST
MAX
SET
360
o
6
23,500
i2,300
44.8
62.7
26.4
o
B
D
C
A
16 Rope Data