For IP transport in original Intraplex T1 or E1 systems, insert the CM-30R module into the same slot
number as the MA-230 module adapter in either a 3RU multiplexer or a 1RU multiplexer.
Table 3-1. CM-30R Indicator Light Descriptions
Light
Color
Description
WAN
100 Lnk/Act
Green
The Ethernet link is established at 100 Mbps, and the blinking light indicates
activity.
OFF
There is no activity.
WAN
10 Lnk/Act
Green
The Ethernet link is established at 10 Mbps, and blinking light indicates activity.
OFF
There is no activity.
WAN
FD
Green
The Ethernet link is full-duplex.
OFF
The Ethernet link is half-duplex.
LAN
100 Lnk/Act
Green
The Ethernet link is established at 100 Mbps, and blinking light indicates activity.
OFF
There is no activity.
LAN
10 Lnk/Act
Green
The Ethernet link is established at 10 Mbps, and blinking light indicates activity.
OFF
There is no activity.
LAN
FD
Green
The Ethernet link is full-duplex.
OFF
The Ethernet link is half-duplex.
LPBK
Yellow
Any CM-30R loopback is enabled.
OFF
Any CM-30R loopback is disabled.
TIMG
Green
The system timing is locked.
Yellow
There is a timing alert.
Red
There is a timing alarm.
OFF
The system timing is unlocked.
ACTIVE
Green
The module is active (online).
Yellow
There is an active alert.
Red
There is an active alarm.
OFF
The module is not active (offline).
STATUS
Green
The module is not reporting an alarm or alert.
Yellow
The module is reporting an alert.
Red
The module is reporting an alarm.
3.2.2.2 CM-30R Switches and Contacts
Table 3-2 gives CM-30R switch settings.
Table 3-2. CM-30R Switch Settings
IP CFG
RESET
Effect
ON
ON
Set the system to factory default settings.
ON
OFF
On system restart, revert the LAN interface to the factory default IP address:
192.168.1.1
OFF
ON
Start up with streams out of service and the default TDM Bus Map.
OFF
OFF
On system restart, the module retains the latest configurations.