NetXpress LX & CM-30R Installation & Operation Manual
5
–
Testing & Troubleshooting
Version 1.1
5-2
GatesAir, Inc.
Intraplex Products
Figure 5-2. NetXpress LX Web Interface Home Page
The
Home
page shows the power module, CM-30 common module, and all channel modules installed
in the multiplexer, including each module’s indicator lights. The power module’s
Normal
green
indicator light should be on, and its
Major
(red) and
Minor
(yellow) indicator lights should be off. The
CM-30R
module’s
WAN
,
Timing
, and
Active
green indicator lights should be on. The
LAN
indicator
light is green if there is a cable connection. If a loopback is configured, the LAN indicator light is
yellow, the multiplexer
Minor
Alert yellow light is on, and the
Normal
green light is off (appears
gray). The green
Service
light for each channel module should be on, and the green
Remote
light
should be on to allow for remote configuration.
Also, the shade of each channel module panel is
white
when in normal operation,
yellow
when
reporting an Alert (Minor alarm), or
red
when reporting an Alarm (Major alarm).
5.1.2
CM-30R Alarm Test
You need to clear any alarms and alarm history before conducting the next tests (Sections 5.1.3 and
5.1.4). Then you can check any current alarms and alarm history information. Perform these steps:
1.
On the navigation pane, point to
Faults
and click
Current
Alarms
(Figure 5-3). Alarms might
appear upon initial power-up but should self-clear on a properly configured system.