4.3.3.3 TDM Bus Information
The
TDM Bus Information
page (Figure 4-27) shows signaling and time slot activity information for
the NetXpress LX TDM busses and to set the system bus mode, E1 or T1. To access the page, point to
System Cfg
and click
TDM
Bus
. Once this page appears, you can also click the edit button to change
loopback/ signaling configuration for each
TDM
Bus
(Figure 4-29).
Figure 4-27. TDM Bus Information Page
Refresh:
Click
M
to refresh the browser manually, or click
5s
,
10s
, or
30s
to automatically refresh
the browser at 5, 10, or 30 second intervals.
TDM Bus:
The specific TDM bus location.
Signaling:
Shows the signaling mode for the bus, either
None
or
CAS
(channel associated signaling)
in E1 mode or
RBS
(robbed bit signaling) in T1 mode.
Timeslot Activity:
The TDM bus time slot tables. Thirty-two time slots appear for an E1 system, and
twenty-four appear for a T1 system. The time slot color codes are:
●
Activity in Timeslot:
Green indicates a channel module is writing data to the time slot.
●
No Activity in Timeslot:
Gray indicates no channel module is writing data to the time slot.
●
Loopback in Timeslot:
Yellow indicates the time slot has been placed in either internal or
external loopback.
●
Conflict in Timeslot:
Red indicates multiple channel modules on the bus are trying to write data
to the same time slot(s).