Signaling Configuration
Use Signaling:
Select this check box to enable E-lead and M-lead circuit signaling. The audio channel
is still operational even if signaling is disabled.
Set C Bit to 1:
Select this check box to force the C bit to be on for compatibility.
Loopbacks
Local:
Click the
On
option to enable a local loopback. Click the
Off
option to disable the loopback. For
testing purposes, a loopback sends the input channel audio and signaling to its own local output
channel.
Channels 1-4:
Click the
On
option to enable a loopback on the specific channel, or click the
Off
option to disable the loopback. When a remote loopback is active (
On
), the local channel module
sends a loopback command to the far end channel module. The far end module continues to process
the incoming receive side data and sends it to the user as usual but also loops that data to the
transmit side of the module, processes it and returns the data to the originating module.
Refresh:
Click this button to refresh the browser.
Submit:
Click this button to apply the configuration values entered on this page.
Reset:
Click this button to reverse all changes to this page.
Previous Card:
Click this button to view configuration and status pages for the module on the
immediate left of this module.
Next Card:
Click this button to view configuration and status pages for the module on the immediate
right of this module.