NetXpress LX & CM-30R Installation & Operation Manual
4
–
Configuration & Operation
Version 1.1
4-84
GatesAir, Inc.
Intraplex Products
Figure 4-76. PT-353 Status Page
Alias Name:
The name you specify for the module to help identify the module type.
Shelf Name:
The name you specify for the multiplexer shelf housing the module.
Card Address:
Each module must have a unique address in the shelf. Valid addresses are 1 through
36.
TDM Bus:
The TDM bus on which the channel module resides.
Module Adapter:
The type of module adapter being used with the module.
Remote Control:
The mode of operation the module is set to use:
REMOTE
or
LOCAL
.
Enable Module:
Select this check box to place the module in service. If not selected, the module is
offline.
Module Configured:
Whether the module is properly configured.
In Service:
Whether the module is in service (green) or out of service gray).
Alarm:
If there is an active alarm (red) or alert (yellow) on the module.
Config Error:
Either a configuration error or normal condition. A configuration error occurs when the
time slot for the module is conflicting with another module in the system or when the number of
occupied time slots exceeds system availability.
Refresh:
Shows if the automatic browser refresh is enabled for 1 minute (
M
), 5 seconds (
5s
), 10
seconds (
10s
), or 30 seconds (
30s
). Click a rate to change how frequently the browser refreshes this
page.