NetXpress LX & CM-30R Installation & Operation Manual
4
–
Configuration & Operation
Version 1.1
4-6
GatesAir, Inc.
Intraplex Products
Figure 4-7. System Cfg | Software Images Configuration
5.
Change the
Primary FPGA Image Filename
to an E1 FPGA file name.
Note:
Application and FPGA files intended for use on the CM-30R will use a file naming convention of
CM30R
_APP_V##.D and
CM30R
_FPGA_XYZ#.bin while those for use on the earlier model
CM-30 are named as
CM30
_APP_V##.D
CM30
_FPGA_XYZ#.bin.
6.
Click
Submit
.
7.
Click
Reset the System
.
To change the system setting back from E1 to T1, repeat these steps, clicking the
T1
option in Step 2
and changing to a T1 FPGA file name in Step 5.
4.2.3.5 Stream Creation
1.
Click
Streams
(Figure 4-8).