NetXpress LX & CM-30R Installation & Operation Manual
4
–
Configuration & Operation
Version 1.1
4-8
GatesAir, Inc.
Intraplex Products
Figure 4-10. Stream Creation
–
Stage 2
4.
On the
Stage 2
:
Stream Features
page, perform these steps:
a.
Click the level of
Forward Error Correction
for the stream (
None
,
Low
,
or
High
; default is
None
).
b.
Click a
Transmission Type
for the stream (
Unicast
,
Multicast
, or
Multi-Unicast
; default is
Unicast
). If you selected
Receive
in
Stage 2
,
Multi-Unicast
is not an available
Transmission Type
.
c.
Select the
Enable Voice Signaling
check box for a signaling stream.
d.
Type the
Statistics Measurement Interval
if different than
5
(default is
5
).
e.
Click
Next
to advance to
Stage 3
(Figure 4-11).
Figure 4-11. Stream Creation
–
Stage 3 for Multi-Unicast
5.
On the
Stage 3
:
IP Config
page, perform these steps:
a.
Type the
Destination IP Address
.
b.
Type the
Local UDP Port
.
c.
Type the
Remote UDP Port
.
d.
For a
CoS Priority
other than
Normal
, click an option (
Low
,
Medium
, or
High
; default is
Normal
).
e.
To change the packet
Time-To-Live
period, type a number at
Egress IP Pkts. TTL
(default
is
5
).
Note:
For multi-unicast streams, remember to repeat the previous 5 steps for all stream
tabs.