1. OPERATIONAL OVERVIEW
1-52
1. Place the cursor in the [ALR1] or [ALR2] box as appropriate, then press the left
button. The cursor jumps into the operational display area and the indication
"SET" appears inside the target alarm box selected.
2. Using the Trackball, move the cursor to Point A, then press the
left button
.
3. Using the Trackball, move the cursor to Point B, then press the
left button
.
“SET” is replaced with “WORK” in the [ALR1] box indication. The target alert
zone’s lines are shown as dashed lines.
Note 1:
To create a 360° alert zone, set Point B at the same location as Point A.
Note 2:
Two alarm zones can be set simultaneously. The second alarm zone is only
available when the first alert zone is active, however.
Note 3:
When the target alarm zone is not within the range in use the indication "UP
RNG" appears to the right of the target alarm box. In this case select a range that will
display the target alarm zone.
1.37.2
How to mute the target alert
A target in the target alert zone produces both visual (flashing) and audible (beep)
alarms. To silence the audio alarm select the appropriate target alert box then press
the
left button
. The target alert box indication shows "ALR
u
MUTE". This will deacti-
vate the audio alarm but will not stop the flashing of the offending target. You can also
stop the alert by deactivating the target alert zone (see section 1.37.3).
To reactivate the audio alert, select the target alert box then press the
left button
until
the target alert box shows "ALR
u
WORK".
1.37.3
How to deactivate a target alert
Select the target box to be deactivated, then press and hold the
left button
.
Note:
When both [ALR1] and [ALR2] are active, [ALR2] must be deactivated before
[ALR1] can be deactivated.
If [ALR1] and [ALR2] are active when you try to deactivate [ALR1], the system releas-
es two audible beeps and shows the message "DELETE ALR2 FIRST".
ALR1 SET
ALR2
ALR1 WORK
ALR2
ALR1 selected and
highlighted
ALR1 ready to be set
X
X
X
X
X
X
000
010
020
030
040
050
060
070
080
090
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
A
B
Target
alert
zone
Other alert zone examples
Point A
Point A
Point A
Point B
Point B
Point B
Содержание FAR-1416
Страница 90: ...2 RADAR OBSERVATION 2 8 This page is intentionally left blank ...
Страница 116: ...4 AIS OPERATION 4 10 This page is intentionally left blank ...
Страница 172: ...5 VIDEO PLOTTER OPERATION 5 56 This page is intentionally left blank ...
Страница 186: ...6 DATA SAVE AND READ 6 14 This page is intentionally left blank ...
Страница 222: ...FURUNO FAR 1416 1426 SP 4 E3650S01D M This page is intentionally left blank ...