Turn the heat sink upside down and check if all four blue washers are in
place, see
. Ensure that no screw falls out.
▶
Carefully seat the heat sink onto the CPU socket.
Take care of the pins. There is only one position which fits.
▶
Fasten the four captive screws in the sequence printed on the heat sink (1 to
4) by hand, by proceeding as follows:
Torque: 1.4 Nm (not used in Japan)
▶
At first, fasten the captive screws 1 and 2 completely.
▶
Fasten the captive screws 3 and 4 completely.
Upgrading the main memory
▶
Select an adequate memory configuration for "2 CPUs populated", see
"Basic information" on page 409
▶
"Installing memory modules" on page 401
.
Concluding steps
▶
"Installing the system air duct" on page 68
.
▶
▶
"Connecting the power cord" on page 82
▶
"Switching on the server" on page 83
Processor (CPU)
TX2550 M5
Upgrade and Maintenance Manual
419
Содержание PRIMERGY TX2550 M5
Страница 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Страница 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 590: ...FUJITSU Server PRIMERGY TX2550 M5 System Cabling Overview System Cabling Overview English Cable plan for May 2019 ...
Страница 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...