To improve the contact of the memory module perform the following
steps:
▶
Eject the memory module again by pressing out the securing clips at each
end of the memory slot.
▶
Press down on the memory module until the securing clips snap into the
cutouts at each end of the module.
▶
Check if all securing clips are in the correct position, see
Concluding steps
▶
"Installing the system air duct" on page 68
.
▶
▶
"Connecting the power cord" on page 82
▶
"Switching on the server" on page 83
▶
"Resuming BitLocker functionality" on page 130
.
10.4
Removing memory modules
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools:
tool-less
CAUTION
▶
Use only released configurations to ensure a faultless operation of
the system.
▶
Before changing the memory configuration, verify if the
configuration is released. Please contact your sales outlet or our
customer service center.
Main memory
TX2550 M5
Upgrade and Maintenance Manual
403
Содержание PRIMERGY TX2550 M5
Страница 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Страница 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 590: ...FUJITSU Server PRIMERGY TX2550 M5 System Cabling Overview System Cabling Overview English Cable plan for May 2019 ...
Страница 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...