Removing a 3.5-inch HDD dummy module
Figure 90: Removing the 3.5-inch dummy module
▶
Press both tabs together (1) and pull the dummy module out of its bay (2).
CAUTION
▶
Keep the dummy module for future use.
▶
Always replace dummy modules into unused HDD/SSD bays to
comply with applicable EMC regulations and satisfy cooling
requirements.
Installing a 3.5-inch HDD module
Figure 91: Opening the locking lever
▶
Pinch the green locking clip (1) and open the locking lever (2).
Hard disk drive (HDD) / solid state disk (SSD)
178
Upgrade and Maintenance Manual
TX2550 M5