Removing the socket cover
Figure 266: Removing the socket cover
▶
Remove the socket cover and save it for future use.
Installing the CPU and heat sink
CAUTION
When replacing a system board
▶
Use a magnifying glass (recommended) to inspect the socket
spring contacts for damages from different angles. Do not use the
spare system board if any irregularities are visible. Possible
damages:
–
Contact spring is bent backwards upon itself
–
Contact spring tip position is shifted or out of alignment
▶
Never try to fix bent contact springs. Doing so may result in loss of
electrical performance and reliability.
▶
Confirm that the CPU model number printed on the top of the CPU fits with
the requirements.
Processor (CPU)
TX2550 M5
Upgrade and Maintenance Manual
413
Содержание PRIMERGY TX2550 M5
Страница 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Страница 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 590: ...FUJITSU Server PRIMERGY TX2550 M5 System Cabling Overview System Cabling Overview English Cable plan for May 2019 ...
Страница 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...