Choose the
Recovery_L
option from the update tool menu to start the iRMC
update process.
CAUTION
If the process is interrupted, the iRMC may be permanently
corrupted.
▶
Do not interrupt the iRMC upgrade process after it has started.
If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
▶
Shut down the server by pressing the power On/Off button.
▶
Disconnect the server from the mains to exit the iRMC recovery state.
5.3.2
Verifying system information backup or restore
To avoid the loss of non-default settings when replacing the system board, a
backup copy of important system configuration data is automatically stored
from the system board NVRAM to the Chassis ID EPROM. After replacing the
system board the backup data is restored from the Chassis ID board to the
new system board.
In order to verify whether the backup or restore process has been successful,
check the System Event Log (SEL) using the ServerView Operations Manager,
see
"Viewing and clearing the System Event Log (SEL)" on page 127
.
After replacing the system board
▶
Check the SEL log files to verify whether the backup data on the Chassis ID
EPROM has been restored to the system board, see
the System Event Log (SEL)" on page 127
Chassis IDPROM: Motherboard Exchange detected
Chassis IDPROM: BMC FW restore successful
Chassis IDPROM: BIOS restore successful
For replacing the system board, the BIOS has an automatic restore
function for the BIOS settings. If the BIOS settings could not be restored
after replacing the system board, you must manually change the
settings.
Basic software procedures
114
Upgrade and Maintenance Manual
TX2550 M5
Содержание PRIMERGY TX2550 M5
Страница 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Страница 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 590: ...FUJITSU Server PRIMERGY TX2550 M5 System Cabling Overview System Cabling Overview English Cable plan for May 2019 ...
Страница 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...