"Resuming BitLocker functionality" on page 130
7.7.2
Replacing the PCIe SSD backplane on the 8x 2.5-
inch PCIe SSD extension box
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
▶
"Shutting down the server" on page 49
▶
"Disconnecting the power cord" on page 50
▶
Remove all 2.5-inch PCIe SSDs SFF from the PCIe SSD extension box, see
"Removing 2.5-inch HDD/SSD modules" on page 220
▶
"Getting access to the component" on page 51
▶
"Removing the system air duct" on page 67
▶
If applicable, remove the fan bridge, see
.
Removing the defective PCIe SSD backplane
▶
Unlock and pull the 8x 2.5-inch PCIe SSD extension box out of its
installation bays, see
"Removing the 8x 2.5-inch HDD/SSD extension box"
.
The PCIe SSD extension box has the same cage as the 8x 2.5-inch
HDD extension box but instead of the two HDD backplanes, there are
two PCIe SSD backplanes.
Hard disk drive (HDD) / solid state disk (SSD)
294
Upgrade and Maintenance Manual
TX2550 M5
Содержание PRIMERGY TX2550 M5
Страница 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Страница 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 590: ...FUJITSU Server PRIMERGY TX2550 M5 System Cabling Overview System Cabling Overview English Cable plan for May 2019 ...
Страница 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...