Preliminary steps
▶
When working on a floorstand model, open the HDD bay cover, see
"Removing the accessible drive bay cover" on page 63
.
▶
Locate the correct drive bay, see
"2.5-inch HDD/SSD configurations" on
.
▶
Depending on your OS (see the "NVMe User Guide"):
Removing a 2.5-inch HDD/SSD dummy module
Figure 126: Removing a 2.5-inch HDD/SSD dummy module
▶
Press both tabs together (1) and pull the dummy module out of its bay (2).
CAUTION
▶
Keep the dummy module for future use.
▶
Always replace dummy modules into unused HDD/SSD bays to
comply with applicable EMC regulations and satisfy cooling
requirements.
Hard disk drive (HDD) / solid state disk (SSD)
226
Upgrade and Maintenance Manual
TX2550 M5
Содержание PRIMERGY TX2550 M5
Страница 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Страница 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 590: ...FUJITSU Server PRIMERGY TX2550 M5 System Cabling Overview System Cabling Overview English Cable plan for May 2019 ...
Страница 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...