Figure 343: Removing the right side cover (B)
▶
Slide the right side cover towards the server rear as far as it will go.
▶
Ensure that the three hooks on the right side cover rest in the wide ends of
the slots on the upper chassis edge (see close-up).
▶
Remove the three hooks on the right side cover from the slots on the upper
chassis edge:
▶
Using a slotted screw driver, slightly pry up on the middle hook until it
disengages (1).
▶
Pull up both ends of the right side cover to remove the left and right
hooks from the slots on the upper chassis edge (2).
▶
Ensure that all cables and components are properly secured inside the
server and that there are no loose pieces.
▶
Carefully turn the server upside down.
At least two people are needed to turn over a completely equipped
server. Remove HDDs and PSUs in order to facilitate the task.
Converting a floorstand model to a rack model
532
Upgrade and Maintenance Manual
TX2550 M5
Содержание PRIMERGY TX2550 M5
Страница 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Страница 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 590: ...FUJITSU Server PRIMERGY TX2550 M5 System Cabling Overview System Cabling Overview English Cable plan for May 2019 ...
Страница 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...