task. Otherwise, the boot watchdog might initiate a system reboot before the
flash process is complete.
CAUTION
An incomplete firmware upgrade process may render the server
inaccessible or result in damaged/destroyed hardware.
Timer settings can be configured in the BIOS or using the ServerView iRMC
web interface.
Disabling the boot watchdog in the BIOS
▶
Enter the BIOS.
▶
Select the
Server Mgmt
menu.
▶
Under
Boot Watchdog
set the
Action
setting to
Continue
.
▶
Save your changes and exit the BIOS.
For more information on BIOS settings, see the corresponding BIOS
Setup Utility reference manual.
Disabling the boot watchdog using the iRMC web interface
▶
Log in to the ServerView iRMC web interface.
▶
Select the
Settings
menu.
▶
Open the
Server Management
page.
▶
In the
Boot Watchdog
group, check the
Enable Boot Watchdog
option.
The
Enable Boot Watchdog
option must be selected.
▶
Select
Continue
from the
Watchdog Action
list.
▶
Click
Apply
for the changes to take effect.
For more information on iRMC settings, see the iRMC user guides.
Basic software procedures
TX2550 M5
Upgrade and Maintenance Manual
109
Содержание PRIMERGY TX2550 M5
Страница 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Страница 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 590: ...FUJITSU Server PRIMERGY TX2550 M5 System Cabling Overview System Cabling Overview English Cable plan for May 2019 ...
Страница 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...