Loosen the captive screws (circles) following the sequence described below
and using a PH2 screwdriver:
CAUTION
▶
Do not use an electric screwdriver.
There is a possibility the washer on the heat sink mounting screw
may be damaged. Ensure to follow the removing procedure as below.
▶
Loosen the four captive screws one by one (in the sequence 4 to 1)
rotating them a half-turn each.
▶
Loosen the captive screws 4 and then 3 rotating them two or three turns
each.
▶
Repeat the step 2 until the screws 4 and 3 are completely loosened.
▶
Loosen the captive screws 2 and then 1 rotating them two or three turns
each.
▶
Repeat the step 4 until the screws 2 and 1 are completely loosened.
▶
Lift the heat sink together with the CPU frame out of the chassis.
CAUTION
▶
Pay special attention not to damage any system board
components surrounding the CPU socket.
Processor (CPU)
422
Upgrade and Maintenance Manual
TX2550 M5
Содержание PRIMERGY TX2550 M5
Страница 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Страница 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 590: ...FUJITSU Server PRIMERGY TX2550 M5 System Cabling Overview System Cabling Overview English Cable plan for May 2019 ...
Страница 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...