Installing a 2.5-inch PCIe SSD module
Figure 127: Opening the locking lever
▶
Pinch the green locking clips (1) and open the locking lever (2).
Figure 128: Installing the 2.5-inch PCIe SSD module
▶
Insert the PCIe SSD module into a drive bay and carefully push back as far
as it will go (1).
▶
Close the locking lever to lock the PCIe SSD module in place (2).
Concluding steps
▶
When working on a floorstand model, close the HDD bay cover, see
"Installing the accessible drive bay cover" on page 78
▶
"Switching on the server" on page 83
Hard disk drive (HDD) / solid state disk (SSD)
TX2550 M5
Upgrade and Maintenance Manual