Preliminary steps
▶
If the HDD module to be removed is combined into a RAID array, please
proceed as follows:
RAID level
Procedure
RAID 0
CAUTION
RAID 0 provides no data redundancy.
In case of an HDD module is defect, all
data are lost!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID
5 array will not result in data loss. However, the
removed drive needs to be replaced immediately
by an HDD module of the same or larger capacity.
After replacing the HDD module, RAID
rebuild will be performed as a background
process, see
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using ServerView
RAID Manager.
CAUTION
All data on all HDDs in the array will be lost when deleting the RAID
array!
▶
Be sure to back up your data before deleting a RAID array.
▶
For more information, see the "ServerView Suite RAID
Management" user guide.
▶
When working on a floorstand model, open the HDD bay cover, see
"Removing the accessible drive bay cover" on page 63
.
Removing a 3.5-inch HDD module
▶
Pinch the green locking clips and open the locking lever, see
▶
Pull the HDD module out a few centimeters.
Hard disk drive (HDD) / solid state disk (SSD)
180
Upgrade and Maintenance Manual
TX2550 M5
Содержание PRIMERGY TX2550 M5
Страница 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Страница 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 590: ...FUJITSU Server PRIMERGY TX2550 M5 System Cabling Overview System Cabling Overview English Cable plan for May 2019 ...
Страница 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...