Figure 221: Removing the slot cover (B)
▶
Remove the slot cover.
CAUTION
▶
Keep the slot cover for future use.
▶
If the expansion card is removed and not replaced with a new one,
the slot cover must be reinstalled due to cooling, to comply with
applicable EMC regulations and to protect against fire.
Installing the expansion card
If an optional FBU will be installed in the system, install a TFM on the
RAID controller, before proceeding.
"Installing a TFM" on page 372
.
▶
Remove the expansion card from its protective packaging.
For more instructions regarding controller settings, see the
accompanying documentation.
▶
If applicable, attach the required slot bracket to the expansion card, see
"Installing a slot bracket" on page 328
.
▶
If applicable, connect internal cables to the expansion card.
Expansion cards and backup units
348
Upgrade and Maintenance Manual
TX2550 M5
Содержание PRIMERGY TX2550 M5
Страница 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Страница 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 590: ...FUJITSU Server PRIMERGY TX2550 M5 System Cabling Overview System Cabling Overview English Cable plan for May 2019 ...
Страница 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...