Note for removing a hot-plug PSU from a redundant configuration
If a hot-plug PSU should be removed from a redundant configuration, while the
system is in operation, proceed the following:
▶
Disconnect the power cord from the dedicated PSU, see
A CSS error is detected and the message "redundancy lost" is displayed
using the iRMC web interface. Your configuration is now non-redundant. The
CSS error is only an information. After removing the PSU out of its bay, the
CSS error will be cleared automatically.
Note for servers using CMA (Cable Management Arm)
Regarding of removing PSUs, additional tasks are needed, due to an
interference between CMA and the PSUs.
▶
If applicable, open the CMA of the server below to get enough space at the
under side of your server.
▶
Unlock the CMA stopper of the server below.
▶
Pull out the CMA of the server below to the rear side.
Figure 66: Unlocking the CMA stopper
Power supply unit (PSU)
TX2550 M5
Upgrade and Maintenance Manual
149
Содержание PRIMERGY TX2550 M5
Страница 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Страница 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 590: ...FUJITSU Server PRIMERGY TX2550 M5 System Cabling Overview System Cabling Overview English Cable plan for May 2019 ...
Страница 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...